Join the 155,000+ IMP followers

www.automation-mag.com

Signal Conditioners for Temperature and 4-20 mA Loops

Phoenix Contact expands MINI Analog Pro with temperature transducer, output isolator and repeater power supply for three-way isolated signal conditioning in 6.2 mm.

  www.phoenixcontact.com
Signal Conditioners for Temperature and 4-20 mA Loops

Analog signals from temperature sensors, field transmitters and control outputs must be isolated, converted and protected before they reach a controller or a field device, while space in control cabinets for process and factory automation remains limited. Phoenix Contact has expanded its MINI Analog Pro family of 6.2 mm wide signal conditioners with three new product types: a temperature transducer, an output isolator and a repeater power supply, presented at SPS 2026, held from 24 to 26 November 2026 in Nuremberg, Germany.

Why Galvanic Isolation Matters in Analog Signal Conditioning
Ground loops, potential differences and interference can distort 4 to 20 mA measurement signals or damage control system input cards. Signal conditioners with galvanic isolation decouple the field side from the control side. All three new devices provide continuous three-way galvanic isolation between input, output and supply, an application-friendly operating and configuration concept, and the benefits of a seamless, scalable system portfolio. They extend the range of signal conditioning tasks the family covers and allow more flexible adaptation to different requirements in process and factory automation.

Temperature Transducer for RTD and Thermocouple Inputs
The MINI MCR-2-T-I(-PT) temperature transducer supports all common temperature sensors, including resistance temperature detectors (RTD), thermocouples and linear resistances, and converts the input signals precisely into 4 to 20 mA standard signals. Configuration is carried out with the clipx Engineer software or on mobile devices via the Signal Conditioner App in combination with an optional Bluetooth adapter.

Output Isolator with HART Transparency
The MINI MCR-2-IDS-I-I(-PT) output isolator transmits analog 0/4 to 20 mA output signals safely from the control level to the field devices. HART signals are passed through transparently, so digital communication with HART-capable field devices remains possible over the isolated loop. Functions such as short-circuit and open-circuit detection can be activated or deactivated using DIP switches.

Repeater Power Supply with Voltage Output
With the MINI MCR-2-RPS-I-U(-PT) repeater power supply, Phoenix Contact adds a variant with voltage output to the portfolio. The device supplies 4 to 20 mA field transmitters and provides the galvanically isolated output signal as a voltage of 0(2) to 10 V. Current-based field signals can thus be integrated simply and safely into applications with voltage inputs.

Installation, Wiring and System Integration
Pluggable terminal blocks with screw or Push-in connection technology and optional power bridging via the DIN rail bus connector reduce wiring effort. Combined with current measurement during operation, this makes installation and commissioning faster and more efficient. The narrow design allows optimum use of space in the control cabinet.

As part of the system portfolio, the new devices are fully compatible with the MACX Analog product family and the Phoenix Contact power supply system. Users benefit from consistent, scalable signal conditioning, straightforward expandability and a central power supply. The robust devices are designed for use in demanding industrial environments and can be used up to Ex zone 2 (protection type "ec").

More information is available on the signal conditioners and measuring transducers page.

Additional Context
This section details technical specifications and competitive benchmarking not included in the original product announcement.

The 4 to 20 mA current loop, described in IEC 60381-1, remains the dominant analog interface in process instrumentation because its live zero enables wire-break detection and the current signal is largely insensitive to cable resistance. Resistance thermometers such as Pt100 are specified in IEC 60751 and thermocouples in IEC 60584; temperature transducers use these characteristic curves for linearisation. The "ec" protection type refers to increased safety according to IEC 60079-7 for equipment in zone 2 hazardous areas. Housing widths of around 6 mm have become a common benchmark for highly compact DIN rail signal conditioners; Weidmüller's ACT20M series, for example, uses a 6 mm housing. Phoenix Contact has not published comparative data on accuracy or power consumption against competing products in this announcement.

Edited by Evgeny Churilov, Induportals Media - Adapted by AI.